Summary: The MICSI-RMT software suite uses a random matrix theory-based algorithm to enhance MRI image quality, improving signal-to-noise ratio and image clarity without external training data or high-performance GPUs, as confirmed by clinical studies.
Key Takeaways
- FDA 510k Clearance: MICSI-RMT software suite has received FDA 510k clearance, validating its clinical application.
- Algorithm and Integration: MICSI-RMT improves MRI image quality using a random matrix theory-based algorithm without needing external training data or high-performance GPUs, and it integrates with medical workflows via DICOM data routing.
- Clinical Study Results: Clinical studies show significant improvements in MRI image clarity, signal-to-noise ratio, and parameter precision, with up to 4.35x SNR improvement for diffusion MRI and better visualization and contrast in brain imaging.
————————————————————————————————————————————————
Microstructure Imaging, Inc. (MICSI), a YCombinator-backed, NYU Langone Health spinout, announces U.S. FDA 510k clearance for its MICSI-RMT software suite, which is designed to enhance MRI image quality. This clearance signifies the clinical application of advanced MRI research led by Gregory Lemberskiy, CEO, and Benjamin Ades-aron, CTO.
MICSI-RMT uses a random matrix theory-based algorithm to improve MRI image quality through the redundancy of the MRI exam. Unlike traditional AI methods, MICSI-RMT does not require external training data or high-performance GPUs. Additionally, MICSI-RMT includes processing modules that support weighted linear least squares and Bayesian fitting techniques for quantitative analysis of diffusion-weighted imaging. Lastly, MICSI-RMT features DICOM data routing for secure and seamless integration into medical workflows.
Clinical Study Insights
- Improved Image Quality: In a randomized, blinded rater study, expert neuroradiologists assessed MRI images processed by MICSI-RMT and the standard of care (SOC). The MICSI-RMT processed images were preferred for their clarity and reduced artifacts, achieving higher expert image quality scores compared to standard diagnostic images. Raters found that DTI images processed with MICSI-RMT had improved visualization of small structures in brain white matter and improved contrast to distinguish adjacent tissue types, and for fMRI, more anatomically appropriate activation maps.
- Significant SNR Improvements: The software demonstrated notable enhancements in the signal-to-noise ratio (SNR), with MICSI-RMT showing improvements of up to 4.35x for diffusion MRI (dMRI) and 1.9x for functional MRI (fMRI).
- Precise Parametric Mapping: dMRI enhancement achieved notable improvement parameter precision. Specifically, the precision of ADC maps was improved by over 56.3%.
Enhancing Neuroimaging Clarity
MICSI-RMT enhances the signal-to-noise ratio (SNR) for diffusion and functional MRI. Diffusion MRI involves exponential signal suppression for contrast, often resulting in images with high noise levels. Similarly, the BOLD effect of functional MRI is only a few percent of the signal, which can easily be obscured by image noise. MICSI-RMT directly addresses the noise problem in these modalities within the clinical workflow.
These enhancements are particularly significant for neuroimaging applications where precise imaging is crucial. In stroke management, especially for lesions of the posterior fossa, and in neurosurgical planning, the improved clarity and accuracy of MRI images directly impact medical decisions. The clinical study focused on critical improvements in these areas, enabling clinicians to make more informed decisions based on clearer imaging data.